DELUGE SYSTEM

RAPHAEL
DELUGE SYSTEM
FDV-DE0

Supplier Distributor Raphael Talis Valve DE0

Raphael Deluge System

Electric Actuated with Local
Reset
Deluge Valve

Raphael Deluge System The FDV is a Fire Protection control valve for Deluge fire
Sprinkler System, designed for installations in hazardous environments

Raphael Fire System Features :
  • Open fail safe valve, maintained in stand-by closed position
  • Hydro-dynamic pattern design ensures
    high flow rates with minimum head loss

Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Pneumatics Air,Nitrogen
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Flange-Flange

Modulating Deluge System

Hydraulic Actuated with
Remote Reset Deluge Valve

Raphael Fire System The FDV-DH1 Deluge system is actuated hydraulically and resets remotely When the Wet pilot detection line’s automatic fire sprinklers are subjected to flame

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flow rates with minimum head loss
  • Soft closing upon pressurization of the valve’s control chamber, by line pressure
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Groove-Groove


RAPHAEL
DELUGE SYSTEM
FDV-DH1

Supplier Distributor Raphael Talis Valve DH1

Modulating Deluge System

Hydraulic Actuated with
Remote Reset Deluge Valve

Raphael Fire System The FDV-DH1 Deluge system is actuated hydraulically and resets remotely When the Wet pilot detection
line’s automatic fire sprinklers are
subjected to flame

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flow rates with minimum head loss
  • Soft closing upon pressurization of the valve’s control chamber, by line pressure
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Groove-Groove


RAPHAEL
DELUGE SYSTEM
FDV-DH1

RAPHAEL
DELUGE SYSTEM
FDV-DA1

Supplier Distributor Raphael Talis Valve DA1

Raphael Deluge System

Hydraulic Actuated & Anti Columning Remote Reset

Raphael Deluge System FDV-DA1 The FDV is a Fire Protection control valve for Deluge fire sprinkler systems, designed for installations in hazardous environments.

Raphael Fire System Features :
  • Soft closing upon pressurization of the valve’s control chamber
  • By line pressure or other independent water source, prevents surges
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Available Connections Ends Flange-Groove
Fluid Water, Brackish water, Sea water, Foam

Raphael Modulating FDV-PE1

Electric Actuated with Remote
Reset Pressure Reducing

The FDV-PE1 is a pressure control Deluge system, actuated electrically and resets remotely. An electric detection systems activates

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
  • Soft closing upon pressurization of the valve’s control chamber, by line pressure
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Fluid Water, Brackish water, Sea water, Foam
Ragulation Ratio 5:1
Sensitivity 1.45 psi (0.1 Bar)
Available Connections Ends Groove-Flange

RAPHAEL
MODULATING
FDV-PE1

Supplier Distributor Raphael Talis Valve PE1

Raphael Modulating
FDV-PE1

Electric Actuated with Remote Reset Pressure Reducing

The Raphael Fire System FDV-PE1 Type is a pressure control Deluge system, actuated electrically and resets remotely. An electric detection systems activates

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
  • Soft closing upon pressurization of the valve’s control chamber, by line pressure
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Fluid Water, Brackish water, Sea water, Foam
Ragulation Ratio 5:1
Sensitivity 1.45 psi (0.1 Bar)
Available Connections Ends Groove-Flange

RAPHAEL
MODULATING
FDV-PE1

RAPHAEL
MODULATING
FDV-PP0

Raphael Modulating FDV-PP0

Pneumatic Actuated with
Local Reset

Designed for vertical or horizontal installation, a globe pattern, line pressure operated FDV-PP0 valve features a direct elastomeric diaphragm seal. It has no balancing spring or internal

Raphael Fire System Features :
  • A pressure reducing pilot enables a full control over the downstream pressure
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Ragulation Ratio up to 5:1
Sensitivity 1.45 psi (0.1 Bar)
Pneumatics Air, Nitrogen
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Thread-Thread

RAPHAEL
MODULATING
FDV-PP0

Raphael Modulating
FDV-PP0

Pneumatic Actuated with
Local Reset

Designed for vertical or horizontal installation, a globe pattern, line pressure operated FDV-PP0 valve features a direct elastomeric diaphragm seal. It has no balancing spring or internal

Raphael Fire System Features :
  • A pressure reducing pilot enables a full control over the downstream pressure
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Ragulation Ratio up to 5:1
Sensitivity 1.45 psi (0.1 Bar)
Pneumatics Air, Nitrogen
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Thread-Thread

Raphael Basic Deluge system

Electric Actuated with Remote
Reset Deluge Valve

The FDV-AE1 is a Fire Protection control valve for Deluge fire sprinkler systems, designed for installations in hazardous environments. The sensors connected to the fire detection Panel

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
  • The valve trips open automatically upon a gradual release of water pressure
  • The valve trips open automatically
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Available Connections Ends Thread-Thread
Fluid Water, Brackish water, Sea water, Foam

RAPHAEL
BASIC DELUGE SYSTEM

Supplier Distributor Raphael Talis Valve AE1

Raphael Basic Deluge system

Electric Actuated with Remote Reset Deluge Valve

The FDV-AE1 is a Fire Protection control valve for Deluge fire sprinkler systems, designed for installations in hazardous environments. The sensors connected to the fire detection Panel

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
  • The valve trips open automatically upon a gradual release of water pressure
  • The valve trips open automatically
Raphael Fire System Series :
Size Range 40mm to 250mm (1½’’ to 10”)
Pressure Nominal 250 psi (17.2 bar)
Available Connections Ends Thread-Thread
Fluid Water, Brackish water, Sea water, Foam

RAPHAEL
BASIC DELUGE SYSTEM

ON/OFF

RAPHAEL
MONITOR VALVE

Supplier Distributor Raphael Talis Valve Monitor Valve

Raphael Monitor Valve

Local Hydraulic Actuated Monitor Valve

The FDV-R-MH0 is a manually operated On-Off Fire Protection Monitor valve, designed to control the opening and closing offire Monitors, in special hazard fire protection systems

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head
  • The valve trips open by manually opening a 3 way ball valve
Raphael Fire System Series :
Size Range 50mm to 200mm (2’’ to 8”)
Pressure Nominal 250 psi (17.2 bar)
Available Connections Ends Flange-Flange, Groove-Groove
Fluid Water, Brackish water, Sea water, Foam

Raphael Hydraulic Hydrants

Local Hydraulic Actuated
Hydrant Valve

The FDV-Ra-HH0 is a hydraulic controlled On-Off Fire Hydrant, designed to connect a pressurized fixed water supply network to a mobile extinguishing unit, through a fire brigade’s quick coupling adapter

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
  • Simple and reliable design
  • Quick respond and fast opening of the valve at emergency situation
Raphael Fire System Series :
Size Range 50mm to 200mm (2’’ to 8”)
Pressure Nominal 250 psi (17.2 bar)
Fluid Water, Brackish water, Sea water
Accessories Upon Request Pressure gauge, Stand pipe, Breakage device
Available Connections Ends Flange-Hose Coupling

RAPHAEL
HYDRAULIC HYDRANTS

Supplier Distributor Raphael Talis Valve Hydraulic Valve

Raphael Hydraulic Hydrants

Local Hydraulic Actuated
Hydrant Valve

The FDV-Ra-HH0 is a hydraulic controlled On-Off Fire Hydrant, designed to connect a pressurized fixed water supply network to a mobile extinguishing unit, through a fire brigade’s quick coupling adapter

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures high flowrates with minimum head loss
  • Simple and reliable design
  • Quick respond and fast opening of the valve at emergency situation
Raphael Fire System Series :
Size Range 50mm to 200mm (2’’ to 8”)
Pressure Nominal 250 psi (17.2 bar)
Fluid Water, Brackish water, Sea water
Accessories Upon Request Pressure gauge, Stand pipe, Breakage device
Available Connections Ends Flange-Hose Coupling

RAPHAEL
HYDRAULIC HYDRANTS

RAPHAEL
MECHANICAL HYDRANTS

Supplier Distributor Raphael Talis Valve Mechanical Valve

Raphael Mechanical Hydrants

Bayard Rethinks The Fire Protection

The Main Purpose Of Hydrants Is The Withdrawal Of Water For Extinguishing Fires. They Are Connected Directly To The Underground Drinking Water Network The Talis Hydrants Are Available In Two Designs, Underground And Stand Post Hydrants

Raphael Fire System Features :
  • Double cut-off with ball on enamelled seat and PUR shut-off cone
  • Safety interlock, stop and anti-rotation grip for the inner fittings
  • Safe water draining through draining valve and draining pipe with dry section
Raphael Fire System Series :
  • Raphael Mechanical Hydrants FDV-HM0
Size Range DN 65-150
Pressure Rating PM 16
Standards EN, DIN, ANSI, NF, BS, UNI, UNE
Material Stainless Steel Components
Upper Part Red Polyester Painting

RAPHAEL
MECHANICAL HYDRANTS

Raphael Mechanical Hydrants

Bayard Rethinks The Fire Protection

The Main Purpose Of Hydrants Is The Withdrawal Of Water For Extinguishing Fires. They Are Connected Directly To The Underground Drinking Water Network The Talis Hydrants Are Available In Two Designs, Underground And Stand Post Hydrants

Raphael Fire System Features :
  • Double cut-off with ball on enamelled seat and PUR shut-off cone
  • Safety interlock, stop and anti-rotation grip for the inner fittings
  • Safe water draining through draining valve and draining pipe with dry section
Raphael Fire System Series :
  • Raphael Mechanical Hydrants
    FDV-HM0
Size Range DN 65-150
Pressure Rating PM 16
Standards EN, DIN, ANSI, NF, BS, UNI, UNE
Material Stainless Steel Components
Upper Part Red Polyester Painting

SERVICE VALVE

Raphael Service Control Valve

Pressure Reducing
Control Valve

Designed for vertical or horizontal installation, the line pressure operated FDV-R-PN2 Pressure reducing valve features a direct elastomeric diaphragm seal with no balancing spring or internal metallic wet components in
the valve body.

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures
  • Simple and reliable design
  • Quick respond to downstream
    pressure changes
  • Pressure reducing to a predetermined
Raphael Fire System Series :
Size Range 40mm to 400mm (1½’’ to 16”)
Pressure Nominal 250 psi (17.2 bar)
Regulation Ratio 5:1
Sensitivity 1.45 psi (0.1 Bar)
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Flange-Flange

RAPHAEL
SERVICE
CONTROL VALVE

Supplier Distributor Raphael Talis Valve Control Valve

Raphael Control Valve

Pressure Reducing
Control Valve

Designed for vertical or horizontal installation, the line pressure operated FDV-R-PN2 Pressure reducing valve features a direct elastomeric diaphragm seal with no balancing spring or internal metallic wet components in the valve body.

Raphael Fire System Features :
  • Hydro-dynamic pattern design ensures
  • Simple and reliable design
  • Quick respond to downstream
    pressure changes
  • Pressure reducing to a predetermined
Raphael Fire System Series :
Size Range 40mm to 400mm (1½’’ to 16”)
Pressure Nominal 250 psi (17.2 bar)
Regulation Ratio 5:1
Sensitivity 1.45 psi (0.1 Bar)
Fluid Water, Brackish water, Sea water, Foam
Available Connections Ends Flange-Flange

RAPHAEL